- 【AMP & VOLT DUAL SIGNAL GENERATOR】- Multifunctional signal generator kit is able to generate ampere & voltage by one module, which generate 0/4 - 20mA current signal and 0-10V voltage signal just by rotating a multi-cycle precise potentiometer, simple and handy.
- 【AMP & VOLT DISPLAY CALIBRATION】- There are current and voltage display calibrating potentiometer on the back of the module. If the display is accurate, you can calibrate the display value of current voltage by yourself.
- 【CLEAR LED DISPLAY】- This 4-20ma signal generator has bright and clear 3-digit LED digital display screen, which can be used to monitor the output current and voltage. You just need to push the switch below the monitor easy to switch the display.
- 【WIDE APPLICATION】- This signal adapter can be used as signal generator, valve adjustment, inverter control, PLC debugging, panel debugging, LED testing, simulating the output of transmitter.
- 【Product Dimension】- 3.93" x 2.67" x 1.49" (100mm x 68mm x 38mm), portable and convenient, easy to use.
- Self-protection signal generator:Built-in one-time quick-break fuse can avoid instrument damages caused by misinserting electric supply with 110V or 220V
- High quality calibrator: Some key chips such as DA, reference voltage and operational amplifier adopts stable chips with high temperature and high temperature, to improve temperature stability of instrument and long-term aging performance index
- Signal Tester:Rational key layout, all functions have independent corresponding keys, which are easily to be operated
- Fast speed and zero delay for key response
- Built-in Battery ,Low power dissipation and long stand-by time
- Power Supply: external micro USB-5V or external power DC 15-30V, each way makes the generator work, both ways also can be connected at the same time.
- Voltage Output: 0-10V, precision is 0.01V, rotate the encoder knob to adjust output voltage, can be calibrated.
- Current Output: 0-22mA, precision is 0.01mA, rotate the encoder knob to adjust output current, can be calibrated.
- Multiple Display: just push the small botton to switch the display mode between voltage and current, you can also follow the instructions to switch 0-100 percent or 0-50HZ display.
- Product Dimension: 3.94” x 2.36” x 0.98” (100mm x 60mm x 25mm), portable and convenient. Note: optional 803040 battery expansibility (battery not included). Please search ASIN "B07PCKCV5K" to get built-in battery generator.
- AMP & VOLT DUAL SIGNAL GENERATOR: Multifunctional DROK signal generator kit is able to generate ampere & voltage by one module, which generate 0/4 - 20mA current signal and 0-10V voltage signal just by rotating a multi-cycle precise potentiometer, simple and handy.
- CLEAR LED DISPLAY: Our 4-20ma signal generator has bright and clear 3-digit LED digital display screen, which can be used to monitor the output current and voltage. You just need to push the switch below the monitor easy to switch the display.
- AMP & VOLT DISPLAY CALIBRATION: There are current and voltage display calibrating potentiometer on the back of the module. If the display is accurate, you can calibrate the display value of current voltage by yourself.
- WIDE APPLICATION: Our signal adapter can be used as signal generator, valve adjustment, inverter control, PLC debugging, panel debugging, LED testing, simulating the output of transmitter.
- Voltage and current and thermocouple measurement and source output
- Basic accuracy 0.2% for measure and source output
- 24V loop supply
- Manual step output for V and mA and auto waveform output.
- The display screen is backlit and the meter has a flashlight on the back
- VERSATILE AND ACCURATE VOLT MA CALIBRATOR: Signal generator, simulator and volt / mA meter for calibrating, testing and repairing milliamp loops, PLC and HVAC systems. Easily generate precise test signals for current and voltage devices (mA, mV and V ranges).
- BUILT-IN 24V LOOP SUPPLY lets you power and read a device or transmitter without needing another multimeter. This greatly simplifies testing 2-wire current loops.
- MEASURE VOLTAGE OUTPUT SIGNALS from process devices and sensors with two input ranges of 0-100mV (0.01mV resolution) and 0-20V (1mV resolution) with 0.02% accuracy. MEASURE CURRENT TRANSMITTERS within a range of 0 to 24mA with 0.001mA resolution and 0.015% accuracy.
- GENERATE PRECISE TEST VOLTAGES AND CURRENTS for testing loops, transmitters, data logger, meters or any devices that measure 4-20mA currents or sensor voltages. Generate voltages in two ranges: 0-100mV with 0.01mV resolution and 0.02% accuracy, and 0-20V with 1mV resolution and 0.02% accuracy. Generate currents within a range of 0 to 24mA with 0.001mA resolution and 0.015% accuracy.
- The eC380V Volt/mA calibrator is powered by six AAA batteries (included). The package includes one eC380V calibrator, 6 AAA batteries, carrying case, test leads, alligator clips adaptors for test leads, and a detailed user manual.
- Fast speed and zero delay for key response
- Built-in Battery, Low power dissipation and long stand-by time
- Signal tester: rational key layout, all functions have independent corresponding keys, which are easily to be operated
- Self-protection signal generator: built-in one-time quick-break fuse can avoid instrument damages caused by misinserting electric supply with 110V or 220V
- High quality calibrator: some key chips such as DA, reference voltage and operational amplifier adopts stable chips with high temperature and high temperature, to improve temperature stability of instrument and long-term aging performance index
- Output: 0 to 20 mA (1 mA increments); 0-10 VDC (1 VDC increments).
- Resolution: 1 mA (current); 1 VDC (voltage).
- Ramping Time Intervals: 1 to 20 sec (1 sec increments).
- Power Requirements: 9 V alkaline battery, included, user replaceable or 120 VAC (provided).
- Auto Power Off: 1 to 20 min.
- It is 2018 MR9270S+,2.4" IPS LCD .bigger LCD than MR9270S
- 1.Smart has powerful performance for it has a high-speed ARM CPU and is easy to get start for it has friendly UI. The following is the structure chart of Smart.
- Moden 4-20mA signal generator calibration Current voltage PT100 thermocouple Pressure transmitter Logger frequency MR9270S
- The menu is in English, with the English documentation and software.
Our Best Choice: MOMOJIA 2-wire 4-20mA Current Loop Signal Generator Panel-mounted Current Transducer Support 2,3,4 wires
[ad_1] 100% model new and significant good quality
Capabilities:
No-supply two-wire 4-20mA latest loop, wiring suitable with 2, 3, 4 wire program
9 programmable output (can simulate the genuine natural environment of dynamic testing, each and every part can be established up t operating time /A present /b recent).
Digital rotary encoder adjustment (the use of potentiometer, effortlessly influenced by temperature and humidity, the resistance price will improve).
Can be linked to the good and negative (two-wire program, no matter how wiring, can function, will not burn off meter).
Significant precision, fantastic linearity (Output accuracy:±0.5%;Display accuracy:0.01)
Coarse and good adjustment modes can be established for quick and accurate adjustment
Output assortment can be established: 4-20mA (control product) / 3-21mA (debug sign)
Exhibit method: Genuine existing/100.%/50.0Hz, Lcd (with backlight).
Linear output, calibratable
Can be set to routinely retailer output values: computerized / manual
2-9 swift adjustment output points can be set
Imported chips, ultra-very low electrical power use, no warmth, additional stable output.
The shell is stunning and simple to install.
No-supply two-wire 4-20mA recent loop, wiring appropriate with 2, 3, 4 wire method
9 programmable output (can simulate the real ecosystem of dynamic testing, every area can be established up t operating time /A existing /b existing).
Electronic rotary encoder adjustment (the use of potentiometer, easily affected by temperature and humidity, the resistance benefit will transform).
Can be linked to the good and negative (two-wire program, no make a difference how wiring, can perform, will not burn meter).
Significant precision, good linearity (Output accuracy:±0.5%;Display accuracy:0.01)